The instrument serves for detecting start and end of precipitation. It can be used as status indicator or as signal transmitter for the controlling of security devices against precipitation such as windows, venetian blinds, awnings.
The precipitation is acquired opto-electronically via a measuring surface of approx. 25 cm². A relays contact signalises the precipitation status (precipitation yes/no).
An integrated heating avoids possible snow-covering resp. freezing of the instrument during winter operation.
Delivery is effected completely with mast holder which can be used also for wall mounting.
Measuring value | Precipitation yes/no |
Switching on | undelayed |
Switch-on condition | 1…15 events selectable in 50 s |
Switch-off delay | 25…375 s selectable in 25s-increments |
Sensor surface | 25 cm² |
Drop size | ≥ 0,2 mm |
Output | Single-pole double throw switch |
Contact load | |
– with 5.4103.10.000 | max. 230 V AC/DC; 4 A |
– with 5.4103.10.700 | max. 60 V AC/DC; 4 A |
Operating voltage | 24 V AC/DC ± 15 % |
Operating current | Approx. 70 mA |
Heating power | max. 1 A |
Ambient temperature | – 30 … + 55 °C |
Protection | IP 65 |
Dimensions | 130 x 140 x 40 mm |
Weight | 0,4 kg |
IEC 61000-6-2: 2005 | Electromagnetic compatibility
Immunity for industrial environment |
IEC 61000-6-3: 2006 | Electromagnetic compatibility Emission standard for residential, commercial and light industrial environments |
IEC 61010-1: 2001 | Safety requirements for electrical equipment for measurement, control and laboratory use. Part 1: General requirements |